1.Background

    With the development of photovoltaic industry, the capacity of village-level transformers and industrial power transformers and the installed capacity of photovoltaic projects are saturated in some areas.The power grid company requires the photovoltaic grid-connected system to be a non-backflow current generation system, which means that the electricity generated by the photovoltaic grid-connected system is consumed by the local load, and the excess electricity is not allowed to be sent to the upper power grid through the low-voltage distribution transformer in reverse direction.

    Photovoltaic inverter in photovoltaic components will produce direct current into alternating current (ac), has the dc component and harmonic mixing, unbalanced three phase current, output power of uncertainty, such as the current basic didn't take effective management measures, therefore, when there is power to the utility grid, will generate harmonic pollution to power network, easy cause power grid voltage fluctuation and flicker, etc.,If there are many such power sources to transmit electricity to the grid, the power quality of the grid will be seriously degraded.Therefore, this kind of photovoltaic power generation system must be equipped with anti-backflow current facilities to prevent the occurrence of reverse power.

    When the photovoltaic power generation is greater than the load demand, the inverse power will be generated.So we need instruments to determine that Inverter has power output, and then by the instrument through RS485 communication signal and inverter data interaction, adjust the inverter output power, so that its output power and power balance.

2.Project Overview

    A photovoltaic power generation company in the Philippines contacted our company to look for anti-backflow current meters. After proper connection agreement, we will purchase ACR10R-D16TE from our company.

3.Anti-backflow detection meter

    When the photovoltaic power generation is greater than the load demand, reverse power will be generated. Therefore, we need an meter to determine that the inverter has over-power output, and then the meter sends a signal through RS485 communication to interact with the inverter data to adjust the output power of the inverter to balance the output power and the electrical power.

1.png

4.Function 

2.png

4.png

5.Wiring


6.Typical Connection

7.png

Bibliography

1.Solutions for enterprise micro-grid system 


 

Contact Us
  • 郵箱:2885080326@qq.com
  • 地址:上海市嘉定區(qū)育綠路253號

掃一掃  微信咨詢

©2025 安科瑞電氣股份有限公司 版權(quán)所有    備案號:滬ICP備05031232號-79    技術(shù)支持:智慧城市網(wǎng)    Sitemap.xml    總訪問量:201726    管理登陸

電瓶車充電樁禁止非法改裝

精品久久香蕉国产线看观看亚洲,躁BBB躁BBB躁BBBBBB,成人乱码一区二区三区AV,精品无码三级在线观看视频

      亚洲欧美在线观看| 扒开女人双腿猛进入爽爽视频视频 | 精品少妇爆乳无码AV无码专区| 国产三级精品三级在线| 97在线公开视频| av免费在线网站| 51网站在线观看免费播放直播足球| 激情又色又爽又黄的A片| 制服丝袜av在线| 激情文学五月天| 国产精品99精品久久免费| 精品国产福利在线| 日本在线综合| xx.av| 久久久18禁一区二区三区| 1000部精品久久久久久久久| 老妇毛茸茸| 国产亚洲 撒尿 小便| gogogo全球高清免费高清观看| JAVBUS老司机论坛| 亚洲色成人一区二区三区小说 | 亚洲国产精品一区| chinesemature老熟妇| 久久精品国产亚洲AV麻豆~| 日韩人妻高清精品专区丨| 精品久久999| a√天堂中文官网8| 国产精品无码一本二本三本色| 国产精品一区二区av白丝下载| 久久激情亚洲| 特黄A又粗又大又黄又爽A片| 精品久久久久久久免费人妻三轩 | 美女av网站| (丰满的女邻居)三级| 天堂资源网| 国产视频在线观看视频| 国产一区二区三区高清在线观看| 天堂在线中文在线| 欧美精产国品一二三区别电影| 91精品国产91久久久久麻豆主演| 色橹橹欧美在线观看视频高清|